external/anthropic-cybersecurity-skills/skills/performing-scada-hmi-security-assessment/SKILL.md
Perform security assessments of SCADA Human-Machine Interface (HMI) systems to identify vulnerabilities in web-based HMIs, thin-client configurations, authentication mechanisms, and communication channels between HMI and PLCs, aligned with IEC 62443 and NIST SP 800-82 guidelines.
npx skillsauth add seikaikyo/dash-skills performing-scada-hmi-security-assessmentInstall this skill globally with one command. Works with Claude Code, Cursor, and Windsurf.
3 of 9 scanners reported clean
Some scanners were skipped, did not run, or reported a non-clean status. Review each row below.
Do not use for testing HMIs in active production without a maintenance window and rollback plan, for PLC-level protocol analysis (see performing-s7comm-protocol-security-analysis), or for general web application testing on non-OT systems.
#!/usr/bin/env python3
"""SCADA HMI Security Assessment Tool.
Evaluates HMI security across authentication, communication,
configuration, and web interface categories aligned with
IEC 62443 and NIST SP 800-82 requirements.
"""
import json
import sys
from datetime import datetime
from typing import Dict, List
try:
import requests
except ImportError:
print("Install requests: pip install requests")
sys.exit(1)
class HMISecurityAssessment:
"""Performs security assessment of SCADA HMI systems."""
def __init__(self, hmi_info: dict):
self.hmi_info = hmi_info
self.findings = []
self.checks_run = 0
self.checks_passed = 0
def check_authentication(self):
"""Assess HMI authentication mechanisms."""
checks = [
{
"id": "AUTH-01",
"name": "Password complexity enforcement",
"iec62443_ref": "ISA-62443-3-3 SR 1.7",
"description": "HMI must enforce minimum password complexity requirements",
"test": "Verify minimum length >= 8, complexity rules, history >= 5",
},
{
"id": "AUTH-02",
"name": "Account lockout policy",
"iec62443_ref": "ISA-62443-3-3 SR 1.11",
"description": "HMI must lock accounts after failed login attempts",
"test": "Verify lockout after 5 failed attempts, lockout duration >= 15 min",
},
{
"id": "AUTH-03",
"name": "Default credentials changed",
"iec62443_ref": "ISA-62443-3-3 SR 1.5",
"description": "All default vendor credentials must be changed",
"test": "Attempt login with known vendor defaults (admin/admin, operator/operator)",
},
{
"id": "AUTH-04",
"name": "Role-based access control",
"iec62443_ref": "ISA-62443-3-3 SR 2.1",
"description": "HMI must separate operator, engineer, and admin roles",
"test": "Verify operator role cannot access engineering functions",
},
{
"id": "AUTH-05",
"name": "Session timeout enforcement",
"iec62443_ref": "ISA-62443-3-3 SR 1.12",
"description": "HMI sessions must time out after inactivity",
"test": "Verify session timeout <= 15 minutes for operator, <= 5 for admin",
},
{
"id": "AUTH-06",
"name": "Multi-factor authentication for remote access",
"iec62443_ref": "ISA-62443-3-3 SR 1.13",
"description": "Remote HMI access requires MFA",
"test": "Verify MFA is enforced for all non-local HMI connections",
},
]
print(f"\n--- AUTHENTICATION ASSESSMENT ---")
for check in checks:
self.checks_run += 1
print(f" [{check['id']}] {check['name']}")
print(f" Ref: {check['iec62443_ref']}")
print(f" Test: {check['test']}")
def check_communication_security(self):
"""Assess HMI-to-PLC communication security."""
checks = [
{
"id": "COMM-01",
"name": "Encrypted HMI-PLC communication",
"description": "Traffic between HMI and PLCs should use encrypted protocols (OPC UA with TLS)",
"test": "Capture HMI-PLC traffic and verify encryption (Wireshark TLS handshake)",
},
{
"id": "COMM-02",
"name": "HMI write command authentication",
"description": "Write commands from HMI to PLC should be authenticated",
"test": "Verify that write operations require operator confirmation/authentication",
},
{
"id": "COMM-03",
"name": "Web HMI uses HTTPS",
"description": "Web-based HMI interfaces must use TLS 1.2+ with valid certificates",
"test": "Check TLS version, cipher suites, certificate validity",
},
{
"id": "COMM-04",
"name": "No cleartext protocols in use",
"description": "Telnet, FTP, HTTP must not be used for HMI access or management",
"test": "Port scan HMI for cleartext protocol services",
},
]
print(f"\n--- COMMUNICATION SECURITY ASSESSMENT ---")
for check in checks:
self.checks_run += 1
print(f" [{check['id']}] {check['name']}")
print(f" Test: {check['test']}")
def check_web_hmi_security(self):
"""Assess web-based HMI for common web vulnerabilities."""
hmi_url = self.hmi_info.get("url", "")
if not hmi_url:
print(f"\n [SKIP] No web HMI URL provided")
return
checks = [
{
"id": "WEB-01",
"name": "Cross-Site Scripting (XSS)",
"owasp": "A7:2017",
"test": "Test input fields with XSS payloads in tag names, alarm messages",
},
{
"id": "WEB-02",
"name": "Cross-Site Request Forgery (CSRF)",
"owasp": "A8:2013",
"test": "Verify CSRF tokens on state-changing operations (setpoint changes)",
},
{
"id": "WEB-03",
"name": "Insecure Direct Object References",
"owasp": "A4:2013",
"test": "Manipulate URL parameters to access other users HMI views",
},
{
"id": "WEB-04",
"name": "Security Headers",
"test": "Verify X-Frame-Options, CSP, X-Content-Type-Options headers",
},
{
"id": "WEB-05",
"name": "Privileged file system access (CVE-2025-0921)",
"test": "Check Ignition SCADA for privileged file system vulnerability via project files",
},
]
print(f"\n--- WEB HMI SECURITY ASSESSMENT ---")
print(f" Target: {hmi_url}")
for check in checks:
self.checks_run += 1
print(f" [{check['id']}] {check['name']}")
print(f" Test: {check['test']}")
def check_hardening(self):
"""Assess HMI operating system and application hardening."""
checks = [
{
"id": "HARD-01",
"name": "OS patch level",
"test": "Verify HMI OS is patched within SLA (typically 90 days for OT)",
},
{
"id": "HARD-02",
"name": "Unnecessary services disabled",
"test": "Verify no unnecessary network services running (RDP if not needed, SMB, etc)",
},
{
"id": "HARD-03",
"name": "USB port restrictions",
"test": "Verify USB mass storage is blocked on HMI terminals",
},
{
"id": "HARD-04",
"name": "Application whitelisting",
"test": "Verify only authorized HMI applications can execute",
},
{
"id": "HARD-05",
"name": "Audit logging enabled",
"test": "Verify operator actions, login events, and setpoint changes are logged",
},
]
print(f"\n--- HMI HARDENING ASSESSMENT ---")
for check in checks:
self.checks_run += 1
print(f" [{check['id']}] {check['name']}")
print(f" Test: {check['test']}")
def generate_report(self):
"""Generate assessment report."""
self.check_authentication()
self.check_communication_security()
self.check_web_hmi_security()
self.check_hardening()
print(f"\n{'='*70}")
print("SCADA HMI SECURITY ASSESSMENT SUMMARY")
print(f"{'='*70}")
print(f"Date: {datetime.now().isoformat()}")
print(f"HMI: {self.hmi_info.get('name', 'Unknown')}")
print(f"Vendor: {self.hmi_info.get('vendor', 'Unknown')}")
print(f"Version: {self.hmi_info.get('version', 'Unknown')}")
print(f"Total Checks: {self.checks_run}")
print(f"Findings: {len(self.findings)}")
if __name__ == "__main__":
assessment = HMISecurityAssessment(hmi_info={
"name": "Plant-HMI-01",
"vendor": "Siemens WinCC",
"version": "7.5 SP2",
"ip": "10.10.2.10",
"url": "https://10.10.2.10:8080",
"os": "Windows 10 LTSC 2021",
})
assessment.generate_report()
| Term | Definition | |------|------------| | HMI | Human-Machine Interface providing operators visual representation and control of industrial processes | | Web HMI | Browser-based HMI interface accessible via HTTP/HTTPS, subject to standard web vulnerabilities | | Setpoint | Target value for a process variable that operators can change through the HMI; unauthorized changes can cause process upset | | Alarm Suppression | Attacker technique of disabling or hiding HMI alarms to mask malicious process manipulation | | WinCC | Siemens SCADA/HMI software widely deployed in manufacturing and process industries | | CVE-2025-0921 | Ignition SCADA privileged file system vulnerability exploitable through malicious project uploads |
HMI SECURITY ASSESSMENT REPORT
=================================
Date: YYYY-MM-DD
HMI: [name] | Vendor: [vendor] | Version: [version]
FINDINGS BY CATEGORY:
Authentication: [pass/fail count]
Communication: [pass/fail count]
Web Security: [pass/fail count]
Hardening: [pass/fail count]
CRITICAL FINDINGS:
1. [finding with remediation]
COMPLIANCE STATUS:
IEC 62443 SL-T: [target level]
IEC 62443 SL-A: [achieved level]
development
拋棄式 HTML mockup 比稿:產出 2 到 3 個設計立場不同的變體(密度 / 版式 / 強調軸,不是換色),各附取捨說明,最後給有立場的對比結論。適用:「畫個草圖」「比較 A 版 B 版」「先看方向再做」「給我看幾種做法」。要 production 元件或設計已定案時不適用。
tools
需求不明時的意圖萃取訪談:一次一題、每題附上自己的猜測、聽出「真正想要 vs 覺得應該要」,直到能預測使用者反應(約 95% 信心)才動工。適用:需求缺少對象 / 動機 / 成功標準 / 約束,或使用者點名「訪談我」「先確認一下」「我們確定嗎」。明確自足的指示、純資訊查詢、機械性操作不適用。
development
對非平凡決策啟動新鮮 context 對抗審查(找碴不背書),在修正還便宜的時候抓出錯誤方向。適用:高風險改動(production、資安敏感邏輯、不可逆操作)、不熟的程式碼、要宣稱「這樣是安全的 / 可行的」之前。機械性操作與一行修改不適用。
testing
Reference for writing and editing agent skills well — the vocabulary and principles that make a skill predictable. Consult when authoring, reviewing, or pruning a SKILL.md.