artifacts/bundle/skills/ra-qm-team/regulatory-affairs-head/SKILL.md
# Head of Regulatory Affairs Regulatory strategy development, submission management, and global market access for medical device organizations. --- ## Table of Contents - [Regulatory Strategy Workflow](#regulatory-strategy-workflow) - [FDA Submission Workflow](#fda-submission-workflow) - [EU MDR Submission Workflow](#eu-mdr-submission-workflow) - [Global Market Access Workflow](#global-market-access-workflow) - [Regulatory Intelligence Workflow](#regulatory-intelligence-workflow) - [Decision
npx skillsauth add neekware/ehayeskills artifacts/bundle/skills/ra-qm-team/regulatory-affairs-headInstall this skill globally with one command. Works with Claude Code, Cursor, and Windsurf.
3 of 9 scanners reported clean
Some scanners were skipped, did not run, or reported a non-clean status. Review each row below.
Regulatory strategy development, submission management, and global market access for medical device organizations.
Develop regulatory strategy aligned with business objectives and product characteristics.
| Factor | 510(k) | De Novo | PMA | | ------------------- | -------------------- | --------------- | ---------------- | | Predicate Available | Yes | No | N/A | | Risk Level | Low-Moderate | Low-Moderate | High | | Clinical Data | Usually not required | May be required | Required | | Review Time | 90 days (MDUFA) | 150 days | 180 days | | User Fee | ~$22K (2024) | ~$135K | ~$440K | | Best For | Me-too devices | Novel low-risk | High-risk, novel |
REGULATORY STRATEGY
Product: [Name] Version: [X.X] Date: [Date]
1. PRODUCT OVERVIEW
Intended use: [One-sentence statement of intended patient population, body site, and clinical purpose]
Device classification: [Class I / II / III]
Technology: [Brief description, e.g., "AI-powered wound-imaging software, SaMD"]
2. TARGET MARKETS & TIMELINE
| Market | Pathway | Priority | Target Date |
|--------|----------------|----------|-------------|
| USA | 510(k) / PMA | 1 | Q1 20XX |
| EU | Class [X] MDR | 2 | Q2 20XX |
3. REGULATORY PATHWAY RATIONALE
FDA: [510(k) / De Novo / PMA] — Predicate: [K-number or "none"]
EU: Class [X] via [Annex IX / X / XI] — NB: [Name or TBD]
Rationale: [2–3 sentences on key factors driving pathway choice]
4. CLINICAL EVIDENCE STRATEGY
Requirements: [Summarize what each market needs, e.g., "510(k): bench + usability; EU Class IIb: PMCF study"]
Approach: [Literature review / Prospective study / Combination]
5. RISKS AND MITIGATION
| Risk | Prob | Impact | Mitigation |
|------------------------------|------|--------|-----------------------------------|
| Predicate delisted by FDA | Low | High | Identify secondary predicate now |
| NB audit backlog | Med | Med | Engage NB 6 months before target |
6. RESOURCE REQUIREMENTS
Budget: $[Amount] Personnel: [FTEs] External: [Consultants / CRO]
Prepare and submit FDA regulatory applications.
| Characteristic | Predicate (K213456) | Subject Device | Same? | Notes | | --------------- | ------------------------------------------------------------------------------------------------------------------------------ | ----------------- | ----- | --------------------- | | Intended use | Wound measurement | Wound measurement | ✓ | Identical | | Technology | 2D camera | 2D + AI analysis | ✗ | New TC; address below | | Energy type | Non-energized | Non-energized | ✓ | | | Patient contact | No | No | ✓ | | | SE conclusion | New TC does not raise new safety/effectiveness questions; bench data demonstrates equivalent accuracy (±2mm vs ±3mm predicate) |
| Milestone | 510(k) | De Novo | PMA | | ------------------ | ---------- | ----------- | ----------- | | Pre-Sub Meeting | Day -90 | Day -90 | Day -120 | | Submission | Day 0 | Day 0 | Day 0 | | RTA Review | Day 15 | Day 15 | Day 45 | | Substantive Review | Days 15–90 | Days 15–150 | Days 45–180 | | Decision | Day 90 | Day 150 | Day 180 |
| Category | Common Issues | Prevention | | ----------------------- | -------------------------------------------------------------- | ------------------------------------------------------------------ | | Substantial Equivalence | Weak predicate comparison; no performance data | Build SE table with data column; cite recognized standards | | Performance Testing | Incomplete protocols; missing worst-case rationale | Follow FDA-recognized standards; document worst-case justification | | Biocompatibility | Missing endpoints; no ISO 10993-1 risk assessment | Complete ISO 10993-1 matrix before testing | | Software | Inadequate hazard analysis; no cybersecurity bill of materials | IEC 62304 compliance + FDA cybersecurity guidance checklist | | Labeling | Inconsistent claims vs. IFU; missing symbols standard | Cross-check label against IFU; cite ISO 15223-1 for symbols |
See: references/fda-submission-guide.md
Achieve CE marking under EU MDR 2017/745.
| GSPR Ref | Requirement | Standard / Guidance | Evidence Document | Status | | ------------- | ----------------------------------------- | ------------------- | ------------------------------- | ----------- | | Annex I §1 | Safe design and manufacture | ISO 14971:2019 | Risk Management File v2.1 | Complete | | Annex I §11.1 | Devices with measuring function ±accuracy | EN ISO 15223-1 | Performance Test Report PT-003 | Complete | | Annex I §17 | Cybersecurity | MDCG 2019-16 | Cybersecurity Assessment CS-001 | In progress |
| Class | Clinical Requirement | Documentation | | ----- | ------------------------------ | ----------------------------------------- | | I | Clinical evaluation (CE) | CE report | | IIa | CE with literature focus | CE report + PMCF plan | | IIb | CE with clinical data | CE report + PMCF + clinical study (some) | | III | CE with clinical investigation | CE report + PMCF + clinical investigation |
See: references/eu-mdr-submission-guide.md
Coordinate regulatory approvals across international markets.
| Market | Size | Complexity | Recognition | Priority | | --------- | ------ | ---------- | -------------- | -------- | | USA | Large | High | N/A | 1 | | EU | Large | High | N/A | 1–2 | | Canada | Medium | Medium | MDSAP | 2 | | Australia | Medium | Low | EU accepted | 2 | | Japan | Large | High | Local clinical | 3 | | China | Large | Very High | Local testing | 3 | | Brazil | Medium | High | GMP inspection | 3–4 |
| Document Type | Single Source | Localization Required | | ------------------- | --------------- | ------------------------------- | | Technical file core | Yes | Format adaptation | | Risk management | Yes | None | | Clinical data | Yes | Bridging assessment | | QMS certificate | Yes (ISO 13485) | Market-specific audit | | Labeling | Master label | Translation, local requirements | | IFU | Master content | Translation, local symbols |
See: references/global-regulatory-pathways.md
Monitor and respond to regulatory changes affecting product portfolio.
| Source | Type | Frequency | | -------------------- | ---------------------- | --------------- | | FDA Federal Register | Regulations, guidance | Daily | | FDA Device Database | 510(k), PMA, recalls | Weekly | | EU Official Journal | MDR/IVDR updates | Weekly | | MDCG Guidance | EU implementation | As published | | ISO/IEC | Standards updates | Quarterly | | Notified Body | Audit findings, trends | Per interaction |
REGULATORY CHANGE IMPACT ASSESSMENT
Change: [Description] Source: [Regulation/Guidance]
Effective Date: [Date] Assessment Date: [Date] Assessed By: [Name]
AFFECTED PRODUCTS
| Product | Impact (H/M/L) | Action Required | Due Date |
|---------|----------------|------------------------|----------|
| [Name] | [H/M/L] | [Specific action] | [Date] |
COMPLIANCE ACTIONS
1. [Action] — Owner: [Name] — Due: [Date]
2. [Action] — Owner: [Name] — Due: [Date]
RESOURCE REQUIREMENTS: Budget $[X] | Personnel [X] hrs
APPROVAL: Regulatory _____________ Date _______ / Management _____________ Date _______
FDA Pathway Selection
Is predicate device available?
│
Yes─┴─No
│ │
▼ ▼
Is device Is risk level
substantially Low-Moderate?
equivalent? │
│ Yes─┴─No
Yes─┴─No │ │
│ │ ▼ ▼
▼ ▼ De Novo PMA
510(k) Consider required
De Novo
or PMA
EU MDR Classification
Is the device active?
│
Yes─┴─No
│ │
▼ ▼
Is it an Does it contact
implant? the body?
│ │
Yes─┴─No Yes─┴─No
│ │ │ │
▼ ▼ ▼ ▼
III IIb Check Class I
contact (measuring/
type sterile if
and applicable)
duration
| Factor | Schedule Pre-Sub | Skip Pre-Sub | | -------------------- | ---------------- | ------------ | | Novel Technology | ✓ | | | New Intended Use | ✓ | | | Complex Testing | ✓ | | | Uncertain Predicate | ✓ | | | Clinical Data Needed | ✓ | | | Well-established | | ✓ | | Clear Predicate | | ✓ | | Standard Testing | | ✓ |
| Situation | Escalation Level | Action | | -------------------- | ---------------- | -------------------------------------- | | Submission rejection | VP Regulatory | Root cause analysis, strategy revision | | Major deficiency | Director | Cross-functional response team | | Timeline at risk | Management | Resource reallocation review | | Regulatory change | VP Regulatory | Portfolio impact assessment | | Safety signal | Executive | Immediate containment and reporting |
| Tool | Purpose | Usage |
| ------------------------------------------------------ | ------------------------------------- | ------------------------------ |
| regulatory_tracker.py | Track submission status and timelines | python regulatory_tracker.py |
Regulatory Tracker Features:
Example usage:
$ python regulatory_tracker.py --report status
Submission Status Report — 2024-11-01
┌──────────────────┬──────────┬────────────┬─────────────┬──────────┐
│ Product │ Market │ Type │ Target Date │ Status │
├──────────────────┼──────────┼────────────┼─────────────┼──────────┤
│ WoundScan Pro │ USA │ 510(k) │ 2024-12-01 │ On Track │
│ WoundScan Pro │ EU │ MDR IIb │ 2025-03-01 │ At Risk │
│ CardioMonitor X1 │ Canada │ Class II │ 2025-01-15 │ On Track │
└──────────────────┴──────────┴────────────┴─────────────┴──────────┘
1 submission at risk: WoundScan Pro EU — NB engagement not confirmed.
| Document | Content | | --------------------------------------------------------------------------- | -------------------------------------------------------------- | | fda-submission-guide.md | FDA pathways, requirements, review process | | eu-mdr-submission-guide.md | MDR classification, technical documentation, clinical evidence | | global-regulatory-pathways.md | Canada, Japan, China, Australia, Brazil requirements | | iso-regulatory-requirements.md | ISO 13485, 14971, 10993, IEC 62304, 62366 requirements |
| KPI | Target | Calculation | | ------------------------ | ------ | ----------------------------------------------------------- | | First-time approval rate | >85% | (Approved without major deficiency / Total submitted) × 100 | | On-time submission | >90% | (Submitted by target date / Total submissions) × 100 | | Review cycle compliance | >95% | (Responses within deadline / Total requests) × 100 | | Regulatory hold time | <20% | (Days on hold / Total review days) × 100 |
| Skill | Integration Point | | ---------------------------------------------------------------- | -------------------------------------- | | mdr-745-specialist | Detailed EU MDR technical requirements | | fda-consultant-specialist | FDA submission deep expertise | | quality-manager-qms-iso13485 | QMS for regulatory compliance | | risk-management-specialist | ISO 14971 risk management |
Creator: Ra Qm Team License: MIT Source Repo:
neekware/ehaye-skillsSource Bucket:ra-qm-teamOriginal Path:ra-qm-team/regulatory-affairs-head
testing
/em -stress-test — Business Assumption Stress Testing
research
/em -postmortem — Honest Analysis of What Went Wrong
development
/em -hard-call — Framework for Decisions With No Good Options
research
/em -challenge — Pre-Mortem Plan Analysis